FY47 - FuturEnergy

Fotovoltaica | PV www.futurenergyweb.es 68 FuturEnergy | Febrero February 2018 colaboración con la Diputación de Valencia, se convocó a principios del pasado mes de noviembre de 2017 un procedimiento negociado sin publicidad que fue adjudicado a las empresas IM2 Systems y Jonsok Autoconsumo, que concurrieron de forma conjunta. El alcance de dicho procedimiento incluía el suministro, instalación y legalización de dos instalaciones solares fotovoltaicas de autoconsumo Tipo 1, de 5 kWde potencia nominal, en los edificios del propio Ayuntamiento y de la nueva Biblioteca, además de otras medidas de mejora como han sido el suministro e instalación de iluminarias LED en un parque público de la población, y en un edificio municipal de multiservicios y eventos. La implantación de equipos principales en las dos instalaciones de autoconsumo ha sido similar. En ambas se han instalado 20 módulos fotovoltaicos del fabricante Astroenergy, modelo ASM6610P de 270Wp, un inversor del fabricante Kaco, modelo Blueplanet 5.0 trifásico de 5 kW y 400 V, y un contador de medida indirecta en punto de frontera del fabricante Circutor. Todo este material ha sido suministrado por la empresa distribuidora Solar Rocket. Sin embargo, la ubicación de cada una de las instalaciones ha sido muy diferente, como se observa en las Figuras 1 y 2, y se describe seguidamente. En el edificio del ayuntamiento se han instalado los módulos coplanarmente sobre un tejado de teja cerámica. Para el cálculo de las pérdidas de sombreado se ha utilizado, además del software PVSyst V4.33, una función adicional de cálculo detallado de sombreado, ya que en esta ubicación es una instalación afectada por la sombra de las edificaciones y muros próximos situados en la zona sur anexa del tejado, tal y como se muestra en la Figura 1. Incluso se ha analizado el posible efecto sombra que puedan provocar los cables de telecomunicaciones que cuelgan por encima del tejado. El resultado de estos análisis fue que el porcentaje de radiación que se pierde es inferior al 20%. Con ello, La producción anual prevista para la instalación de autoconsumo del ayuntamiento es de 6.175 kWh/ año, y el Performance Ratio (PR) calculado para esta instalación es del 66,61%. En el edificio de la nueva Biblioteca, tanto la superficie pisable de acceso a la cubierta, como la propia cubierta sobre la que se deben ubicar los módulos, son del tipo deck, y por tanto más críticas y susceptibles de sufrir problemas de humedades o goteras, por lo que se ha adoptado la solución técnica de instalar los módulos sobre una estructura en businesses and SMEs on how to reduce their energy bill and the environmental impact of energy consumption. The office also works to promote municipal energy saving initiatives and the use of renewable energy. This office analyses options for implementing self-consumption and applies for different connection points from the company Iberdrola Distribución Eléctrica.With this in place, and in collaboration with the Valencia Regional Government, in early November 2017 an unpublished negotiated procedure was opened that was awarded to IM2 Systems and Jonsok Autoconsumo, who had submitted a joint tender. The scope of this tender included the supply, installation and legal validation of two Type 1 solar PV self-consumption installations, each with a 5 kW rated output, for the Town Hall building itself and for the new Library. Other improvement measures included the supply and installation of LED lighting fixtures in one of the town’s public parks and for a municipal multi-facility and events building. The installation of the main self-consumption equipment was the same in both cases. Twenty ASM6610P model PV modules manufactured by Astroenergy were installed on both buildings along with a Blueplanet model 5.0 5 kW and 400 V three-phase inverter from Kaco and an indirect connection energy meter from Circutor. All the material was supplied by distribution company Solar Rocket. However, the positioning of each installation was very different, as shown in Figures 1 and 2, and described as follows. In the case of the Town Hall building, the modules were installed in a coplanar arrangement on top of the tiled roof. To estimate losses from shading, an additional calculation was used, apart from the PVSyst V4.33 software, given that the installation’s position is affected by shadows from nearby buildings and walls located to the south of the roof, as Figure 1 shows. The analysis also included the possible effect that shadows could have on the telecommunications cables crossing the roof. These analyses concluded that the lost radiation percentage was under 20%. As such, the expected annual production for the Town Hall’s self-consumption installation is 6,175 kWh/year, with a calculated Performance Ratio (PR) of 66.61%. For the new Library building, both the treadable surface area to access the roof, and the rooftop itself on which the modules had to be positioned, are of a deck-type construction and as such more critical and likely to suffer from humidity or seepage problems. A technical solution was therefore implemented, installing the modules on a coffered structure on top of the existing roof, made from sandwiched panels to create a skylight Figura 1. Instalación autoconsumo en edificio del Ayuntamiento | Figure 1. Self-consumption installation on the Town Hall building Disposición final coplanar de los 20 módulos fotovoltaicos, optimizando la ubicación en cuanto a espacio y minimizando la afectación de sombreado | Final coplanar arrangement of the 20 PV modules, optimising the location as regards space and minimising the effects of shading Cubierta en estado original de teja cerámica del edificio del Ayuntamiento sobre la que se han instalado los módulos fotovoltaicos y rieles de aluminio sobre teja, sobre los que se atornillan y fijan los módulos fotovoltaicos, en disposición coplanar | Original tiled roof of the Town Hall building on which the PV modules have been installed along with aluminium mounting rails on top of the tiles, on to which the PV modules have been screwed and attached in a coplanar arrangement

RkJQdWJsaXNoZXIy Njg1MjYx