FY28 - FuturEnergy

Redes Urbanas de Frio y Calor | DHC Networks FuturEnergy | Marzo March 2016 www.futurenergyweb.es 43 cimiento mediante el aprovechamiento de la biomasa local, en concreto de la jara. Para ello se están realizando los estudios pertinentes, para poder implantar en la localidad un centro de tratamiento y revalorización de este residuo vegetal, que además de proporcionar el combustible para las necesidades térmicas de la localidad, disminuyendo el coste del kW térmico para los consumidores, permitirá la creación de empleo local. Sistema de control automático de la red de calefacción de El Atazar El equipo de control automático ha sido suministrado por Desner y está compuesto por: • Controlador Automation Server, fabricado por Schneider Electric y programado por Desner Sistemas. CPU situada en la sala de calderas que puede controlar hasta 10.000 variables, 4 GB de memoria, conexión vía Internet, sin límite de acceso de usuarios, y de gran potencia gráfica. Es un sistema escalable, lo que significa que en el futuro en El Atazar se pueden hacer modificaciones y ampliaciones sin problema. • Dispositivo Desner CCM-204, uno por cada edificio. Recoge todas las variables de la vivienda para transmitiras a la CPU. La unión entre los controladores de los edificios y la CPU es un bus BACNET MSTP desplegado por todo el pueblo. Mejoras obtenidas con el control En el mantenimiento: • Detección de averías en tiempo real. Análisis de funcionamiento y envío de alarmas por email. • Posibilidad de resolver la mayor parte de las averías a distancia y cambio de todo tipo de parámetros, variables y consignas vía Internet desde cualquier dispositivo comunicable por web (teléfono, PC, tablet, etc). Ahorro energético: • La lógica de funcionamiento de todos los equipos de la instalación y la instalación en sí se programan amedida y de forma personalizada, lo que redunda en un ahorro energético. substations of each house or consumption point. One of the important aspects of the installation is its regulation and control, as the installation can be monitored via Internet by every network user, as well as by the town hall and any authorised technician. This allows users to find about their current consumption, programme a comfortable temperature in the house and regulate their consumption. The town hall, meanwhile, can control the overall consumption of the network and the maintenance company can anticipate faults in the installation unbeknown to the end user. All of this is possible thanks to the company that undertook the development of the regulation and control system, Desner. The company Multitek executed the entire project as well as being responsible for works management. The thermal plant is currently fed by woodchip produced by nearby distributors however the main aim, and one of the goals of implementing the heating network, is self-supply by making use of local biomass, specifically rockrose. Relevant studies are being undertaken so that a green waste treatment and waste-to-energy plant can be deployed in the village that, apart from supplying the fuel to cover the thermal needs of the village, will also bring down the cost per thermal kW for consumers and lead to the creation of local employment. The El Atazar heating network automatic control system The automatic control equipment was supplied by Desner and comprises: • The Automation Server Controller, manufactured by Schneider Electric and programmed by Desner Sistemas. The CPU located in the boiler room can control up to 10,000 variable points with 4 GB of memory, connection via Internet, unlimited access for users and high-powered graphics. The system is scalable meaning that future modifications and extensions can be made in El Atazar without a problem. • The Desner CCM-204 device, one per building, compiles the different variables of the house for transmission to the

RkJQdWJsaXNoZXIy Njg1MjYx